Encom Digital

Phone: +254 714 962 072 Email: sales@encom.africa Address: Rehema House, C-Suite, 4th Floor, Standard Street, Nairobi

200kVA UPS in Kenya: Price, Full Load Current, Batteries and Which SIEL to Choose

A 200kVA UPS protects up to 200 kW in a data centre, hospital, bank or factory. Here is its full load current, size and weight, how many batteries it needs, what generator suits it, and how the SIEL Safepower S 200K and Evo HF 200K compare.

A 200kVA UPS in Kenya protects up to 200 kW of critical load, so it suits a data centre hall, a large hospital, a bank’s core systems or a whole factory control room. At Encom, you have two choices at this size: the SIEL Safepower S 200K and the SIEL Safepower Evo HF 200K. Both are three-phase online double conversion units that we supply on order and quote per project.

Prices and specs checked on 29 October 2026.

SIEL Safepower Evo HF 200K, a 200kVA UPS for Kenya
SIEL Safepower Evo HF 200K. Image courtesy of SIEL.

Key takeaways

  • Both SIEL 200kVA models give the full 200 kW, because their output power factor is 1.
  • At full load, a 200kVA UPS draws about 289 A per phase on a 400 V three-phase supply.
  • The Safepower S 200K weighs 230 kg, while the Evo HF 200K weighs 460 kg, according to SIEL.
  • Schneider Electric says every 8 °C rise in temperature cuts a lead acid battery’s life in half.
  • A generator for a 200kVA UPS is usually sized at 250 to 400 kVA, that is 1.25 to 2 times the UPS rating.

What is the 200kVA UPS price in Kenya?

There is no shelf price for a 200kVA UPS in Kenya, because the battery bank changes the total so much. For example, 10 minutes of backup at 200 kW needs far fewer batteries than an hour does. So we quote each SIEL unit once we know your load, your runtime and your site. Also, all Encom prices exclude VAT.

In particular, five things move the final figure:

  • The model. Safepower S or Evo HF, since each has its own strengths.
  • The battery bank. Standard VRLA blocks, or lithium (LiFePO4) on the Evo HF.
  • Battery cabinets. At this size, every battery sits in an external cabinet, so the cabinet count follows your runtime.
  • Redundancy. One unit, or two in parallel as N+1 when downtime is not an option.
  • Installation. Cabling, breakers and a bypass panel, as well as delivery to your plant room.

What can a 200kVA UPS run?

Because its power factor is 1, a SIEL 200kVA UPS carries up to 200 kW of running load. For instance, that covers about 20 server racks at 8 kW each, a hospital’s theatres, ICU and labs, or the PLCs and drives of a production line.

However, we advise running a UPS at no more than about 80% of its rating. So a 200kVA unit fits a planned load of about 160 kW. That leaves room for growth, as well as for start-up surges.

Large sites are also growing in Nairobi. For example, Digital Realty opened its 6.4 MW NBO2 facility in Karen in September 2026, as Baxtel reported. That is the same as 32 units of 200 kW, so this size is the building block for many server halls.

Power is still the main reason sites go down. The Uptime Institute’s 2025 outage analysis states that “power remains the leading cause of impactful outages.”

What is the full load current of a 200kVA UPS?

At 400 V three-phase, a 200kVA UPS draws about 289 A per phase at full output. The formula is I = kVA x 1000 / (1.732 x V), so 200,000 / (1.732 x 400) gives 288.7 A.

Supply voltageCurrent per phase at 200 kVA
380 VAbout 304 A
400 VAbout 289 A
415 VAbout 278 A
Calculated with the standard three-phase formula.

These figures help you plan breakers and cables early. Still, cable size also depends on run length and how the cable is laid, so a licensed electrician must confirm it. In Kenya, this work falls under EPRA’s Electrical Installation Work Rules.

Safepower S 200K or Evo HF 200K: which SIEL fits?

Pick the Safepower S 200K for a compact cabinet and a touchscreen, and the Evo HF 200K for larger parallel systems and lithium batteries.

SpecSafepower S 200KEvo HF 200K
Power200 kW200 kW
Online efficiencyUp to 96.5%Up to 96.2%
Units in parallelUp to 4Up to 8
Size (W x D x H)442 x 850 x 1200 mm840 x 1050 x 1900 mm
Weight230 kg460 kg
Battery string30 to 50 blocks40 blocks, VRLA or LiFePO4
Specifications courtesy of SIEL.

When the Safepower S 200K makes sense

SIEL Safepower S 200K three-phase online UPS cabinet
SIEL Safepower S 200K. Image courtesy of SIEL.

The SIEL Safepower S 200K suits plant rooms where space is tight. Its cabinet is only 442 mm wide, so it fits where a wider unit cannot. It also has a 7 inch touchscreen, a diesel mode input and a wide input range of 208 to 478 V, which helps on generator sites.

In addition, its 96.5% efficiency means slightly less heat. At full load, that saves about 5,700 kWh a year compared with 96.2%. However, it runs up to four units in parallel, so its ceiling is 800 kVA.

When the Evo HF 200K makes sense

The SIEL Safepower Evo HF 200K suits sites that plan to grow. Up to eight units can run in parallel, which takes you to 1.6 MW. SIEL also lists a lithium (LiFePO4) battery option for it. SIEL describes the range as “ideal for the protection of computer networks, telecommunications and critical systems in general.”

If your load sits nearer 120 kW, look one step down instead. For example, the Safepower S 150K and the Evo HF 160K cover that gap. Our guide to the 120kVA SIEL models covers the size below that.

How many batteries does a 200kVA UPS need?

The Evo HF 200K uses strings of 40 blocks of 12 V, split 20 + 20 around a centre point. In contrast, the Safepower S 200K accepts 30 to 50 blocks per string. However, SIEL notes that strings of 30 to 34 blocks lower the output power factor to 0.8 or 0.9, so we plan full length strings.

Neither model has room for batteries inside at this size. So every battery sits in external cabinets, and we add strings in parallel for longer backup. The Safepower S 200K also charges at up to 60 A, while the Evo HF 200K charges at up to 25 A. As a result, the Safepower S refills a large bank faster after a long outage.

Heat matters as much as count. Schneider Electric warns that “every 8°C (15°F) increase in temperature will cut the battery’s life in half.” So in Nairobi, Mombasa or Kisumu, keep the battery room cooled to about 20 to 25 °C.

How long will the batteries last in an outage?

Backup time depends on your load and your battery bank, so there is no single answer. For example, a 200kVA UPS at half load runs much longer than one at full load on the same batteries.

Your target also depends on whether you have a generator. According to a Vertiv paper for the Battcon conference, UPS batteries have traditionally been sized for 15 minutes, because the UPS only bridges the gap until the generator takes over.

What size generator suits a 200kVA UPS?

Plan for a generator of about 250 to 400 kVA when it only feeds the UPS. UK specialist UPS Systems suggests a generator of 1.25 to 2 times the UPS output, because a UPS draws a distorted current that heats the alternator.

Consulting-Specifying Engineer warns that “harmonic distortion can cause excessive heating at the generator”, and it notes that a 6-pulse rectifier typically has about 30% THD. By comparison, both SIEL 200K models keep input distortion (THDi) at 3% or less, with an input power factor of 0.99. So they sit at the gentle end, and your set may not need the top of the ratio. Still, your electrician should confirm the final size.

How big is a 200kVA UPS, and how much heat does it give off?

The Safepower S 200K measures 442 x 850 x 1200 mm and weighs 230 kg. Meanwhile, the Evo HF 200K measures 840 x 1050 x 1900 mm and weighs 460 kg. Both figures exclude battery cabinets.

The small footprint has a catch. Because the Safepower S puts 230 kg on about 0.38 square metres, it loads the floor at roughly 610 kg per square metre. The Evo HF works out at about 520. So ask your engineer to check the slab, as well as door widths and lift limits, before delivery day.

At full load, the Evo HF loses about 7.9 kW as heat, while the Safepower S loses about 7.3 kW. In ECO mode at 99%, that falls to about 2 kW. Since both cabinets are IP20 as standard, keep them indoors, cool and away from dust. SIEL rates both for 0 to 40 °C and up to 95% humidity without condensation.

How to get a SIEL quote in Kenya

To quote quickly, we need your load in kW or an equipment list, as well as your supply voltage. We also need your runtime and whether you have a generator. Then we come back with the right model and battery setup. Encom Digital is the only retailer of SIEL in Kenya and East Africa. Request a quote on WhatsApp on +254 714 962 072, or Email us.

For server halls, also read our data centre UPS guide on redundancy and batteries. If you are still working out phases, see how to size a three phase UPS for your site. Finally, compare every range in our SIEL UPS buyer’s guide or browse the critical and industrial UPS range.

Frequently asked questions

Price and buying

What is the 200kVA UPS price in Kenya?

We quote each SIEL 200K per project, because the battery bank for your runtime sets most of the cost. Send us your load and runtime, and we will quote. Also, our prices exclude VAT.

What is the 200kVA UPS with battery price?

It depends on your backup time. Every quote includes batteries and cabinets sized for your runtime, so you see the full cost in one figure.

Where can I buy a SIEL 200kVA UPS in Kenya?

Encom Digital in Nairobi is the only retailer of SIEL UPS systems in Kenya and East Africa. We supply each unit on order, so it is set up for your load.

Sizing and specifications

What is the 200 kVA UPS full load current?

About 289 A per phase at 400 V three-phase. Similarly, it is about 304 A at 380 V and about 278 A at 415 V.

How many kW is a 200kVA UPS?

Both SIEL models give 200 kW, since their power factor is 1. In contrast, a unit rated 0.8 gives only 160 kW.

What are the 200kVA UPS dimensions?

The Safepower S 200K is 442 x 850 x 1200 mm at 230 kg. Meanwhile, the Evo HF 200K is 840 x 1050 x 1900 mm at 460 kg.

Batteries, generators and backup

How many batteries does a 200kVA UPS use?

The Evo HF 200K uses strings of 40 blocks of 12 V. Then we add strings in parallel until you reach your backup time.

Can a 200kVA UPS use lithium batteries?

Yes, on the Evo HF 200K. It ships with VRLA as standard, while LiFePO4 is an option.

Can two 200kVA units run together?

Yes. You can run up to four Safepower S units or up to eight Evo HF units in parallel, for extra capacity or as N+1.

Does a 200kVA UPS work with a generator?

Yes. Because both keep THDi at 3% or less, they are gentle on generators. Even so, plan a set of about 250 to 400 kVA.